Tools Required
J 5790-B Hydraulic
Lifter Leakdown Tester
Important: Components that are to be reused must be marked, sorted or organized
for assembly.
- Mark, sort, or organize the components for assembly.
- Clean the components in cleaning solvent.
Caution: Wear safety glasses in order to avoid eye damage.
- Dry the components with compressed air.
- Inspect the valve lifters
for the following conditions:
• | Scored or worn pushrod socket |
• | Scuffed or worn lifter body |
• | If the valve lifter body shows scuffing or wear, inspect the engine
block valve lifter bores for wear or damage. |
• | The lifter foot should be smooth and slightly convex or flat. |
- Inspect the valve lifter leak down rate. Use the J 5790-B
.
- Replace the lifter if the plunger travel is more than 3.175 mm
(0.125 in) in 12-19 seconds under a 222.4 Newtons (50 lb)
load.
- Inspect the valve lifter guides for cracks or damage.