Removal Procedure
Tools Required
• | J 5403 Snap
Ring Pliers #21 Internal |
- Discharge and remove the refrigerant from the system. Refer to
Refrigerant Recovery and Recharging
.
- Disconnect the electrical connector from the switch in the rear
head of the compressor.
- Remove the switch retaining ring using J 5403
.
- Remove the switch from the compressor.
- Remove the O-ring seal from the switch cavity using J 9553-01
.
Installation Procedure
Tools Required
J 5403 Snap Ring
Pliers #21 Internal
- Install the new O-ring seal, coated with refrigerant oil, into
the groove in the switch cavity.
- Install the switch in the cavity until the switch bottoms in the
cavity. Lubricate the switch housing with refrigerant oil before installing.
- Install the switch retaining ring using J 5403
.
- Connect the electrical connector.
- Add refrigerant to the system. Refer to
Refrigerant Recovery and Recharging
.