Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
DEFINITION: Blower motor is always ON at any selected speed. | ||||
1 | Were you sent here from the HVAC System Check (CJ2)? | -- | Go to HVAC System Check (CJ2) | |
2 |
Is the blower motor on? | -- | ||
3 |
Is the voltage within the specified values? | 10.0-14.0V | ||
4 | Replace the HVAC control head . Is the repair complete? | -- | Go to HVAC System Check (CJ2) | -- |
5 | Replace the blower motor control module. Is the repair complete? | -- | Go to HVAC System Check (CJ2) | -- |
6 | Locate and repair a short to battery power in CKT 63. Is the repair complete? | -- | Go to HVAC System Check (CJ2) | -- |