GM Service Manual Online
For 1990-2009 cars only

Removal Procedure

Tools Required

J 38185 Hose Clamp Pliers

    Caution: With a pressurized cooling system, the coolant temperature in the radiator can be considerably higher than the boiling point of the solution at atmospheric pressure. Removal of the surge tank cap, while the cooling system is hot and under high pressure, causes the solution to boil instantaneously with explosive force. This will cause the solution to spew out over the engine, the fenders, and the person removing the cap. Serious bodily injury may result.

    NOTICE: When adding coolant, it is important that you use GM Goodwrench DEX-COOL® or HAVOLINE® DEX-COOL® coolant. If Coolant other than DEX-COOL® or HAVOLINE® DEX-COOL® is added to the system the engine coolant will require change sooner; at 50 000 km (30,000 mi) or 24 months.

  1. Drain the cooling system. Refer to Cooling System Draining and Filling .

  2. Object Number: 179289  Size: SH
  3. Remove the surge tank hose clamps.
  4. Remove the hoses at the surge tank.
  5. Disconnect the coolant level sensor connector.

  6. Object Number: 64022  Size: SH
  7. Remove the surge tank nuts.
  8. Remove the surge tank.

Installation Procedure


    Object Number: 64022  Size: SH
  1. Install the surge tank.
  2. Important: When installing the surge tank make sure the lower stud is fully seated in the lower bottle slot.

  3. Install the lower surge tank nut.
  4. Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.

  5. Install the two upper surge tank nuts.
  6. Tighten
    Tighten the surge tank nuts to 10 N·m (89 lb in).


    Object Number: 179289  Size: SH
  7. Install the hoses to the surge tank.
  8. Install the surge tank hose clamps.
  9. Connect the coolant level sensor connector.
  10. Fill the cooling system. Refer to Cooling System Draining and Filling .