Blower Motor Medium Speed Inoperative (Position 2) <<C60>>
Step
| Action
| Value(s)
| Yes
| No
|
DEFINITION: Blower motor will operate at all speeds except
medium speed (Position 2).
|
1
| Were you sent here
from the HVAC System Check (C60)?
| --
|
Go to Step 2
| Go to
HVAC System Check
|
2
|
- Disconnect the HVAC Control Assembly connector C2.
- Disconnect the blower motor control module connector C1.
- Connect a fused jumper wire between terminal B and terminal G
of the HVAC Control Assembly connector C2.
- Turn the ignition switch to the ON position.
- Connect the DMM between terminal A of the blower motor control
module connector C1 and a good ground.
- Measure the available voltage at terminal A of the blower motor
control module connector C1.
Is the voltage within the specified range?
| 10.0 -14.0V
|
Go to Step 4
|
Go to Step 3
|
3
| Locate and repair
an open or a high resistance in CKT 63.
Is the repair complete?
| --
| Go to
HVAC System Check
| --
|
4
|
- Remove the fused jumper wire.
- Connect the HVAC Control Assembly connector C2.
- Turn the blower switch to position 2.
- Turn the ignition switch to the ON position.
- Connect the DMM between terminal A of the blower motor control
module connector C1 and ground.
- Measure the available voltage at terminal A of the blower motor
control module connector C1.
Is the voltage within the specified range?
| 10.0 -14.0V
|
Go to Step 6
|
Go to Step 5
|
5
| Replace the HVAC Control
Assembly. Refer to
Control Assembly Replacement
.
Is the repair complete?
| --
| Go to
HVAC System Check
| --
|
6
| Replace the blower motor control module. Refer to
Blower Motor Resistor Replacement
.
Is the repair complete?
| --
| Go to
HVAC System Check
| --
|
Blower Motor Medium Speed Inoperative (Position 3) <<C60>>
Step
| Action
| Value(s)
| Yes
| No
|
DEFINITION: Blower motor will operate at all speeds except
medium speed (Position 3).
|
1
| Were you sent here
from the HVAC System Check (C60)?
| --
|
Go to Step 2
| Go to
HVAC System Check
|
2
|
- Disconnect the HVAC Control Assembly connector C2.
- Disconnect the blower motor control module connector C1.
- Connect a fused jumper wire between terminal B and terminal F
of the HVAC Control Assembly connector C2.
- Turn the ignition switch to the ON position.
- Connect the DMM between terminal D of the blower motor control
module connector C1 and a known good ground.
- Measure the available voltage at terminal D of the blower motor
control module connector C1.
Is the voltage reading within the specified range?
| 10.0 -14.0V
|
Go to Step 4
|
Go to Step
3
|
3
| Locate
and repair an open or a high resistance in CKT 72.
Is the repair complete?
| --
| Go to
HVAC System Check
| --
|
4
|
- Remove the fused jumper wire.
- Connect the HVAC Control Assembly connector C2.
- Turn the blower switch to position 3.
- Turn the ignition switch to the ON position.
- Connect the DMM between terminal D of the blower motor control
module connector C1 and a known good ground.
- Measure the available voltage at terminal D of the blower motor
control module connector C1.
Is the voltage reading within the specified range?
| 10.0 -14.0V
|
Go to Step 6
|
Go to Step
5
|
5
| Replace
the HVAC Control Assembly. Refer to
Control Assembly Replacement
.
Is the replacement complete?
| --
| Go to
HVAC System Check
| --
|
6
| Replace the blower motor control module. Refer to
Blower Motor Resistor Replacement
.
Is the replacement complete?
| --
| Go to
HVAC System Check
| --
|
Blower Motor Medium Speed Inoperative (Position 4) <<C60>>
Step
| Action
| Value(s)
| Yes
| No
|
DEFINITION: Blower motor will operate at all speed except
medium speed (Position 4).
|
1
| Were you sent here
from the HVAC System Check (C60)?
| --
|
Go to Step 2
| Go to
HVAC System Check
|
2
|
- Disconnect the HVAC Control Assembly connector C2.
- Disconnect the blower motor control module connector C1.
- Connect a fused jumper wire between terminal B and terminal E
of the HVAC Control Assembly connector C2.
- Turn the ignition switch to the ON position.
- Connect the DMM between terminal C of the blower motor control
module connector C1 and a known good ground.
- Measure the available voltage at terminal C of the blower motor
control module connector C1.
Is the voltage reading within the specified range?
| 10.0 -14.0V
|
Go to Step 4
|
Go to Step
3
|
3
| Locate
and repair an open or a high resistance in CKT 73.
Is the repair complete?
| --
| Go to
HVAC System Check
| --
|
4
|
- Remove the fused jumper wire.
- Connect the HVAC Control Assembly connector C2.
- Turn the blower switch to position 4.
- Turn the ignition switch to the ON position.
- Connect the DMM between terminal C of the blower motor control
module connector C1 and a known good ground.
- Measure the available voltage at terminal C of the blower motor
control module connector C1.
Is the voltage within the specified range?
| 10.0 -14.0V
|
Go to Step 6
|
Go to Step 5
|
5
| Replace the HVAC Control
Assembly. Refer to
Control Assembly Replacement
.
Is the replacement complete?
| --
| Go to
HVAC System Check
| --
|
6
| Replace the blower motor control module. Refer to
Blower Motor Resistor Replacement
.
Is the replacement complete?
| --
| Go to
HVAC System Check
| --
|