Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
DEFINITION: Blower motor operates at all speeds except high (position 5). | ||||
1 | Were you sent here from the HVAC System Check (C60)? | -- | Go to HVAC System Check | |
2 |
Is the voltage within the specified values? | 10.0 -14.0V | ||
3 |
Is CKT 52 continuous between the HVAC Control Assembly connector C2 and the blower motor module connector C1? | -- | ||
4 | Replace the HVAC Control Assembly. Refer to Control Assembly Replacement . Is the repair complete? | -- | Go to HVAC System Check | -- |
5 | Locate and repair an open or a high resistance in CKT 52. Is the repair complete? | -- | Go to HVAC System Check | -- |
6 |
Is the voltage within the specified values? | 10.0 -14.0V | ||
7 | Locate and repair an open or a high resistance in CKT 1342 between the instrument panel electrical center and the blower motor control module connector C1. Is the repair complete? | -- | Go to HVAC System Check | -- |
8 | Replace the blower motor control module. Refer to Blower Motor Resistor Replacement . Is the repair complete? | -- | Go to HVAC System Check | -- |