Step
| Action
| Value(s)
| Yes
| No
|
1
| Were you
sent here from the Interior Lights System Check?
| --
|
Go to Step 2
| Go to
Interior Lamps System Check
|
2
|
- Connect a DMM between the inoperative IP storage compartment lamp
connector terminal B and ground.
- Measure for continuity to ground in the CKT 150.
Is the CKT 150 continuous to ground?
| --
|
Go to Step 4
|
Go to Step
3
|
3
| Repair CKT 150 for an open.
Is the repair complete?
| --
| Go to
Interior Lamps System Check
| --
|
4
|
- Connect the DMM between the inoperative IP storage compartment
lamp connector terminal A and ground.
- Remove the CTSY LP Micro Relay #42 from the Instrument Panel Electrical
Center.
- Connect a fuse jumper between the BAT terminal and the CKT 740
terminal (which is used for the CTSY LP Micro Relay #42) in the Instrument
Panel Electrical Center.
- Measure the available voltage at the IP storage compartment lamp
connector.
Is the measured voltage within the specified value?
| 10.0-14.0V
|
Go to Step 8
|
Go to Step 5
|
5
| Check the C/LALDL MiniFuse ®
#29 for an open circuit.
Is the fuse open?
| --
|
Go to Step 7
|
Go to Step 6
|
6
| Repair CKT
740 for an open.
Is the repair complete?
| --
| Go to
Interior Lamps System Check
| --
|
7
| Repair CKT 740 for a short to ground.
Is the repair complete?
| --
| Go to
Interior Lamps System Check
| --
|
8
| Replace the IP storage compartment lamp.
Refer to
Instrument Panel Compartment Lamp Replacement
.
Is the repair complete?
| --
| Go to
Interior Lamps System Check
| --
|