Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
DEFINITION: The fuel tank filler door lock actuator solenoid will not release. | ||||
1 | Were you sent here from the Fuel Filler Door Release System Check? | -- | ||
2 |
Is the voltage within the specified values? | 10.0-14.0V | ||
3 | Check the F/TNKDR MiniFuse® #32 for an open circuit. Is the fuse open? | -- | ||
4 | Replace the F/TNKDR MiniFuse® #32. Does the F/TNKDR MiniFuse® #32 immediately open when installed? | -- | ||
5 | Repair a short to ground in CKT 2840. Is the repair complete? | -- | -- | |
6 | Repair the open in CKT 2840. Is the repair complete? | -- | -- | |
7 |
Does the F/TNKDR MiniFuse® #32 immediately open when the button is depressed? | -- | ||
8 | Repair a short to ground in CKT 79. Is the repair complete? | -- | -- | |
9 |
Is continuity present across the fuel tank filler door lock release switch when the button is depressed? | -- | ||
10 |
Is the voltage within the specified values? | 10.0-14.0V | ||
11 | Repair the open in CKT 79. Is the repair complete? | -- | -- | |
12 |
Is CKT 150 continuous to ground? | -- | ||
13 | Repair the open in CKT 150 from the fuel tank filler door lock actuator solenoid connector to G302. Is the repair complete? | -- | -- | |
14 |
Refer to Fuel Tank Filler Door Lock Actuator Replacement Is the repair complete? | -- | -- | |
15 | Replace the fuel tank filler door lock release switch. Refer to Fuel Tank Filler Door Lock Release Switch Replacement Is the repair complete? | -- | -- |