The solar sensor is a photo-electric cell that provides sunload input to the HVAC Control Assembly. The input for the sunload is at terminal C2 of the HVAC Control Assembly. This is used by the HVAC Control Assembly for temperature control compensation based on additional heat from the sun (sunload).
The HVAC Control Assembly continuously monitors CKT 590. DTC B0348 will set when CKT 590 stays at 4.5 volts or higher.
• | Stores a DTC B0348 in the HVAC Control Assembly memory. |
• | The system will default and assume no solar load is present. |
• | Use the IPC clearing feature. |
• | Using a scan tool. |
• | A history DTC will clear after 50 consecutive ignition cycles if the condition for the fault is no longer present. |
• | If the DTC is a history or intermittent. Try performing the tests shown while moving the wiring harnesses and connectors, this can often cause the malfunction to appear. |
• | Visually inspect sensor connector and harness for damage, corrosion or water intrusion. |
• | Check for adequate terminal tension, mis-routed harness, rubbed through wire insulation, and broken wire(s) inside the insulation. |
The numbers below refer to the step numbers on the diagnostic table:
This test checks for the 5 volt reference signal being sent from the HVAC Control Assembly along CKT 590.
Check for an open in CKT 590.
This step is checking for continuity of CKT 1798.
Repair open in CKT 1798 between HVAC Control Assembly and sun load temperature sensor.
This step will replace the sun load temperature sensor.
Erase all DTCs and recheck for repair verification.
Replace the HVAC Control Assembly.
Repair the open in CKT 590.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Were you sent here from the HVAC System Check (CJ2)? | -- | Go to HVAC System Check | |
2 |
Is the voltage within the specified values? | 4.0-6.0V | ||
3 |
Is the resistance within specified values? | 0-2 ohms | ||
4 | Use a DMM to measure the voltage between terminal A and terminal B of the sun load temperature sensor connector. Is the voltage within the specified values? | 4.0-6.0V | ||
5 | Locate and repair an open or a high resistance in CKT 1798 between the sun load temperature sensor connector and HVAC Control Assembly. Is the repair complete? | -- | -- | |
6 | Replace the sun load temperature sensor. Refer to Sun Load Sensor Replacement . Is the repair complete? | -- | -- | |
7 | Using the scan tool, clear all DTCs from memory. Refer to Diagnostic Trouble Code (DTC) Clearing . Do all DTCs erase from memory? | -- | Go to HVAC System Check | Go to appropriate DTC table for diagnosis |
8 | Replace the HVAC Control Assembly. Refer to Control Assembly Replacement . Is the repair complete? | -- | -- | |
9 | Locate and repair an open or a high resistance in CKT 590. Is the repair complete? | -- | -- |