The BCM provides control for the RH DRL relay circuit. The BCM grounds CKT 1966 in order to energize the RH DRL relay and turn ON the RF turn signal. This allows the RF turn signal to be used for DRL, UTD, and approach lighting functions. The BCM monitors the voltage level on CKT 1966. When the BCM commands the relay ON, the voltage level on CKT 1966 should be low. When the relay is OFF, the voltage on CKT 1966 should be high. If the BCM detects a voltage level other than expected, a malfunction is present and a DTC will set.
• | The BCM detects a high voltage level (a short to voltage or BCM open internally) in CKT 1966. |
• | The BCM can only test for this condition with the RH DRL relay energized. |
• | This condition must be present for 2 seconds. |
• | Stores a DTC B0503 in the BCM memory. |
• | No driver warning message will be displayed for this DTC. |
• | This DTC requires an ignition cycle in order to change from current to history. |
• | The BCM no longer detects a high voltage level in CKT 1966 only with the RH DRL relay energized. |
• | A history DTC will clear after 50 consecutive ignition cycles if the condition for the malfunction is no longer present. |
• | Use the IPC clearing DTCs feature. |
• | Use a scan tool. |
• | The following conditions may cause an intermittent malfunction: |
- | There is an intermittent open or short to voltage in CKT 1966. |
- | There is low resistance in the relay coil. |
- | There are poor connections at the BCM, the I/P electrical center, or the RH DRL relay terminals. |
- | The RH DRL relay is shorted to voltage internally. |
• | If the BCM is open internally, or if CKT 1966 is shorted to voltage, the RH DRL will remain OFF at all times, but the RH turn signal will still function normally. |
• | If the DTC is a history DTC, the problem may be intermittent. Perform the tests shown while moving related wiring and connectors. This can often cause the malfunction to occur. Refer to Intermittents and Poor Connections Diagnosis . |
The numbers below refer to the step numbers on the diagnostic table:
This test determines if there is an open in the I/P electrical center or fuse.
This test checks the RH DRL relay control circuit by using a scan tool to command the BCM to energize the RH DRL relay ON and OFF.
This test determines if there is a short to voltage in CKT 1966.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Were you sent here from the BCM Diagnostic System Check? | -- | ||
Is the test light ON? | -- | |||
Does the test light turn ON and OFF with each command? | -- | |||
Check for a short to voltage in CKT 1966. Was a problem found and repaired? | -- | |||
5 | Check for poor connections at the RH DRL relay. Was a problem found and repaired? | -- | ||
6 | Check for poor connections at the harness connector of the body control module. Was a problem found and repaired? | -- | ||
7 |
Is the circuit repair complete? | -- | -- | |
8 | Replace the RH DRL relay. Is the replacement complete? | -- | -- | |
9 |
Is the replacement complete? | -- | -- | |
10 |
Is the repair complete? | -- | -- |