Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Were you sent here from the HVAC Diagnostic System Check? | -- | Go to Diagnostic System Check | |
2 |
Does the test light illuminate? | -- | ||
3 |
Is CKT 52 continuous between the HVAC Control Assembly connector C2 and the blower motor module connector C1? | -- | ||
4 | Replace the HVAC Control Assembly. Refer to Control Assembly Replacement . Is the repair complete? | -- | -- | |
5 | Locate and repair the open or high resistance in CKT 52. Is the repair complete? | -- | -- | |
6 | Connect a test light between the blower motor control module connector C1 terminal G and ground. Does the test light illuminate? | -- | ||
7 | Locate and repair the open or high resistance in CKT 1342 between the instrument panel electrical center and the blower motor control module connector C1. Is the repair complete? | -- | -- | |
8 | Replace the blower motor control module. Refer to Blower Motor Resistor Replacement . Is the repair complete? | -- | -- | |
9 |
Did you correct the condition? | -- | System OK | Go to Diagnostic System Check |