Removal Procedure
- Remove the IP upper trim
pad. Refer to
Instrument Panel Upper Trim Pad Replacement
in Instrument Panel, Gauges and Console.
- Disconnect the RH side window defogger lower outlet duct from
the windshield defroster duct, then reposition the side window defogger duct
forward.
- Disconnect the vacuum harness connectors from the defroster actuator.
- Rotate the defrost door lever fully rearward (counterclockwise),
then carefully insert a flat bladed tool between the bottom of the defrost
door lever and the protruding wall of the HVAC module case below the door
lever in order to keep the door lever in place.
- Lift to release the defroster
actuator retaining tab and begin to slide the actuator toward the passenger
SIR bracket.
- Carefully rotate the defroster actuator upward and forward until
the actuator clears the passenger SIR bracket.
- Disconnect the defroster
actuator pushrod from the defrost door lever and remove the actuator.
Installation Procedure
- Connect the defroster
actuator pushrod to the defrost door lever.
- Position the defroster
actuator along side of the passenger SIR bracket in line with the mounting
pins on the HVAC module case.
- Carefully rotate the defroster actuator past the passenger SIR
bracket, rearward and downward, until the actuator slots align with the HVAC
module mounting pins.
- Inspect that the defroster actuator pushrod is not binding on
the defrost door lever.
- Push the defroster actuator toward the HVAC module case to secure
the retaining tab.
- Remove the flat bladed
tool maintaining the defrost door lever in position.
- Connect both of the vacuum harness connectors to the defroster
actuator.
- Position and connect the RH side window defogger lower outlet
duct to the windshield defroster duct.
- Install the IP upper trim pad. Refer to
Instrument Panel Upper Trim Pad Replacement
in Instrument Panel, Gauges and
Console.