Removal Procedure
- Loosen the air cleaner
duct clamp at MAF sensor.
- Remove the air cleaner assembly bolts.
- Remove the air cleaner assembly.
Installation Procedure
- Install air cleaner assembly
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the air
cleaner assembly bolts.
Tighten
Tighten the bolt to 18 NĀ·m (13 lb ft).
Notice:
ā¢ | Handle the MAF sensor carefully. |
ā¢ | Do not drop the MAF sensor in order to prevent damage to the MAF
sensor. |
ā¢ | Do not damage the screen located on the air inlet
end of the MAF. |
ā¢ | Do not touch the sensing elements. |
ā¢ | Do not allow solvents and lubricants to come in contact with the
sensing elements. |
ā¢ | Use a small amount of a soap based solution in order to aid in
the installation. |
- Install air cleaner duct to MAF sensor.