Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
DEFINITION: All stop lamps are always on. | ||||
1 | Review the stoplamp operation and perform the necessary inspections. Did you complete the system review and inspection? | -- | Go to Step 2 | Go to Symptoms |
2 | Attempt to operate the stoplamps. Does the system operate normally? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 | Disconnect the TCC/Stoplamp switch. Did the stoplamps remain on? | -- | ||
4 | Disconnect the connector C202 at the convenience center. Did the stoplamps remain on? | -- | ||
5 | Repair the short to voltage in CKT 17 (WHT) between the TCC/Stoplamp switch and connector C202. Did you complete the repair? | -- | -- | |
6 | Disconnect connector C404. Did the stoplamps remain on? | -- | ||
7 | Repair the short to voltage between connector C404 and the left stoplamp. Did you complete the repair? | -- | -- | |
8 | Disconnect connector C401. Did the stoplamps remain on? | -- | ||
9 | Repair the short to voltage between connector C401 and the right stoplamp. Did you complete the repair? | -- | -- | |
10 | Repair the short to voltage in the wiring harness between C202 and connectors C401/404. Did you complete the repair? | -- | -- | |
11 | Replace the TCC/Stoplamp switch. Is the repair complete? | -- | -- | |
12 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |