Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Exterior Lights System Check? | -- | Go to Step 2 | |
2 |
Does the test lamp flash? | -- | Go to Step 3 | Go to Step 4 |
3 | Replace the hazard switch. Refer to Hazard Flasher Switch Replacement in Instrument Panel, Gauges and Console. Is the repair complete? | -- | -- | |
4 | Repair the open in CKT 15 between the hazard switch and the right IP wiring harness junction block. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- |
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Exterior Lights System Check? | -- | Go to Step 2 | |
2 |
Does the test lamp light? | -- | Go to Step 3 | Go to Step 4 |
3 | Connect a test lamp between terminal B and terminal A of the hazard switch connector. Does the test lamp light? | -- | Go to Step 5 | Go to Step 6 |
4 | Backprobe the left IP junction block connector C1 with a test lamp between terminal C12 and ground. Does the test lamp light? | -- | Go to Step 7 | Go to Step 8 |
5 | Replace the hazard switch. Refer to Hazard Flasher Switch Replacement in Instrument Panel, Gauges and Console. Is the repair complete? | -- | -- | |
6 | Repair the open in CKT 150 between the hazard switch and ground splice pack G201. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
7 | Repair the open in CKT 1140 between the hazard switch and the left IP junction block. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
8 | Replace the left IP junction block. Refer to Relay/Fuse Center Replacement in Wiring Systems. Is the repair complete? | -- | -- |