Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Interior Lamps System Check? | -- | Go to Step 2 | |
2 |
Does the resistance measure within the specified range? | 0-2 ohms | Go to Step 3 | Go to Step 4 |
3 | Use the J 39200 DMM in order to measure the voltage between terminal A of the vanity mirror lamp connector and ground. Does the voltage measure to the specified value? | B+ | Go to Step 5 | Go to Step 6 |
4 | Repair the open in CKT 750 between the right vanity mirror lamp and ground splice pack G401. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
5 | Replace the right vanity mirror lamp. Refer to Sunshade Replacement in Interior Trim. Is the repair complete? | -- | -- | |
6 | Use the J 39200 DMM in order to backprobe the left IP junction block connector C3. Measure the voltage between terminal C4 and ground. Does the voltage measure to the specified value? | B+ | Go to Step 7 | Go to Step 8 |
7 | Repair the open in CKT 1732 between the left IP junction block and the right vanity mirror lamp. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
8 | Replace the left IP junction block. Refer to Relay/Fuse Center Replacement in Wiring Systems. Is the repair complete? | -- | -- |