Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was A Diagnostic System Check performed? | -- | Go to Step 2 | |
2 | Visually inspect the 10 Amp HAZARD LPS fuse for an open. Is an open present? | -- | Go to Step 3 | Go to Step 6 |
3 | With the hazard switch open, test the Fuse Output-Battery circuit for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and repair the condition? | -- | System OK | Go to Step 4 |
4 | Check Turn Signal Lamp Feed-Left Front Circuit for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and repair the condition? | -- | System OK | Go to Step 5 |
5 | Check Turn Signal Lamp Feed-Right Front Circuit for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and repair the condition? | -- | System OK | -- |
6 | With the hazard switch removed, test the Fuse Output-Battery circuit at the hazard switch connector for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and repair the condition? | -- | System OK | Go to Step 7 |
7 | Replace the hazard switch. Refer to Hazard Warning Switch Replacement in Instrument Cluster. Did you complete the procedure? | -- | System OK | -- |