Removal Procedure
- Disable the SIR system.
Refer to
Disabling the SIR System
in
SIR.
- Remove the instrument panel cluster trim plate from the IP carrier.
Refer to
Instrument Cluster Trim Panel Replacement
.
- Disconnect the hazard warning switch electrical connector if required.
- Disconnect the electrical connector from the dimmer switch (2).
- With a small flat-bladed tool gently pry on the release tabs (1)
for the dimmer switch (2).
- Remove the dimmer switch (2) by pushing in a inward motion
while holding onto the instrument panel cluster trim plate.
Installation Procedure
- Install the dimmer switch (2)
into the instrument panel cluster trim plate.
- With light pressure push the dimmer switch (2) into the
instrument panel cluster trim plate until fully seated inside tabs (1).
- Connect the electrical connector to the dimmer switch (2).
- Connect the hazard warning switch electrical connector if required.
- Install the instrument cluster trim plate to the IP Carrier. Refer
to
Instrument Cluster Trim Panel Replacement
.
- Enable the SIR system. Refer to
Enabling the SIR System
in SIR.