Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the Charging System Check performed? | -- | Go to Step 2 | Go to Charging System Check |
2 |
Does the charge indicator light? | -- | Go to Step 3 | Go to Step 4 |
3 | Remove the generator and replace the IC regulator. Refer to Generator Replacement and Generator Overhaul . Is the repair complete? | -- | Go to Charging System Check | -- |
4 |
Does the charge indicator light? | -- | Go to Step 5 | Go to Step 6 |
5 | Repair the open in the WHT/RED wire between the instrument cluster connector 1 terminal 1 and the generator. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Charging System Check | -- |
6 | Test for an open in the BLK/WHT wire between the instrument cluster connector 1 terminal 2 and the junction block (including S241 and S242). Was an open found? | -- | Go to Step 8 | Go to Step 7 |
7 | Inspect the instrument cluster printed circuit for cracks and bad connections. Repair or replace as necessary. Is the repair complete? | -- | Go to Charging System Check | -- |
8 | Repair the open. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Charging System Check | -- |