Step | Action | Value(s) | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
1 | Did you perform the Instrument Cluster Diagnostic System Check? | -- | Go to Step 2 | |||||
2 |
Does the ECT gauge indicate C? | -- | Go to Step 3 | Go to Step 4 | ||||
3 | Replace the ECT sensor. Is the repair complete? | -- | -- | |||||
4 |
Is the measured resistance less than the specified range? | ∞ | Go to Step 5 | Go to Step 6 | ||||
5 | Repair the short to ground in the YEL/WHT wire between the IP cluster assembly and the ECT sensor. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |||||
6 | Inspect the IP cluster printed circuit for the following conditions:
Are the connections OK? | -- | Go to Step 7 | Go to Step 8 | ||||
7 | Replace the ECT gauge. Is the repair complete? | -- | -- | |||||
8 | Replace the instrument panel cluster printed circuit. Refer to Printed Instrument Cluster Circuit Replacement in Instrument Panel , Gauges, and Console. Is the repair complete? | -- | -- |