Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the defogger system check? | -- | Go to Step 2 | Go to Defogger System Check |
2 |
Does the test lamp light? | -- | Go to Step 3 | Go to Step 5 |
3 | Inspect for an open in BLK wire between the instrument panel cluster assembly and the junction block. Is the assembly OK? | -- | Go to Step 4 | Go to Step 2 |
4 | Repair/replace the instrument panel cluster printed circuit. Is the repair complete? | -- | Go to Defogger System Check | -- |
5 | Repair an open in RED/WHT wire between S225 and the instrument panel cluster assembly. Is the repair complete? | -- | Go to Defogger System Check | -- |