Step | Action | Value(s) | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
1 | Was the Power Door Lock System Check performed? | -- | Go to Step 2 | |||||
2 | Backprobe the power door lock control module using a J 39200 from terminal 6 to ground. Does the voltage measure greater than the specified value?? | 10 V | Go to Step 4 | Go to Step 3 | ||||
3 | Test for an open in the WHT/GRN wire between the power door lock control module and the junction block. Was an open found? | -- | Go to Step 6 | Go to Step 7 | ||||
4 | Test for an open in the BLK wire between the power door lock control module and G203. Was an open found? | -- | Go to Step 6 | Go to Step 5 | ||||
5 |
Was an open found? | -- | Go to Step 6 | Go to Step 8 | ||||
6 | Repair the open in the wire. Refer to Wiring Repairs in wiring systems. Is the repair complete? | -- | -- | |||||
7 | Replace the junction block. Is the repair complete? | -- | -- | |||||
8 | Replace the power door lock control module. Is the repair complete? | -- | -- |