Step | Action | Value(s) | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
Important: Perform the following steps In order to avoid misdiagnosis:
| ||||||||
1 | Did you perform the HVAC Air Delivery System Check? | -- | Go to Step 2 | |||||
2 | Inspect the fuse block for an open in fuse 4. Is there an open in fuse 4? | -- | Go to Step 3 | Go to Step 4 | ||||
3 | Repair a short to ground in CKT 41 (BRN) . Is the repair complete? | -- | System OK | -- | ||||
4 |
Is the measured voltage within the specified range? | 9-14 V | Go to Step 8 | Go to Step 5 | ||||
5 | Use a DMM in order to probe between the heater-A/C control harness connector C2 terminal B7 and ground. Is the measured voltage within the specified range? | 9-14 V | Go to Step 7 | Go to Step 6 | ||||
6 | Locate and repair a poor connection or open in CKT 41 (BRN) between the fuse block terminal D10 and the heater-A/C control harness connector C2 terminal B7. Is the repair complete? | -- | System OK | -- | ||||
7 | Locate and repair a poor connection or open in CKT 150 (BLK) between the heater-A/C control harness connector C2 terminal B8 and G205. Is the repair complete? | -- | System OK | -- | ||||
8 |
Is the measured voltage within the specified range? | 9-14 V | Go to Step 12 | Go to Step 9 | ||||
9 | Use a DMM in order to probe between the right electric actuator harness connector terminal 10 and ground. Is the measured voltage within the specified range? | 9-14 V | Go to Step 11 | Go to Step 10 | ||||
10 | Locate and repair a poor connection or an open in CKT 41 (BRN) between S233 and the right electric actuator harness connector terminal 10. Is the repair complete? | -- | System OK | -- | ||||
11 | Locate and repair a poor connection or an open in CKT 150 (BLK) between the right electric actuator harness connector terminal 7 and G205. Is the repair complete? | -- | System OK | -- | ||||
12 |
Is the measured voltage within the specified range? | 1-12 V | Go to Step 13 | Go to Step 14 | ||||
13 |
Is the repair complete? | -- | System OK | -- | ||||
14 | Inspect for a short to ground or a short to B+ in CKT 1236 (WHT/BLK) . Does a short to ground or a short to B+ exist in CKT 1236 (WHT/BLK)? | -- | Go to Step 15 | Go to Step 16 | ||||
15 | Repair the short to ground or short to B+ in CKT 1236 (WHT/BLK). Is the repair complete? | -- | System OK | -- | ||||
16 | Inspect for a poor connection or an open in CKT 1236 (WHT/BLK). Does a poor connection or open exist in CKT 1236 (WHT/BLK)? | -- | Go to Step 17 | Go to Step 18 | ||||
17 | Repair the poor connection or open in CKT 1236 (WHT/BLK). Is the repair complete? | -- | System OK | -- | ||||
18 | Replace the heater-A/C control. Refer to Control Assembly Replacement . Is the repair complete? | -- | System OK | -- |