Removal Procedure
Tools Required
J 37088-A Tool Set,
Fuel Line Quick-Connect Separator
Important: Relieve the fuel system pressure before servicing any fuel system connection.
Refer to the Fuel Pressure Relief Procedure.
- Relieve the fuel system pressure. Refer to
Fuel Pressure Relief
- Grasp both sides of the
quick-connect fitting. Twist quick-connect fitting 1/4 turn in each direction
to loosen any dirt within fitting.
- Repeat for other fuel pipe fitting.
Caution: Wear safety glasses when using compressed air in order to prevent eye
injury.
- Blow out dirt from quick-connect
fittings at both ends, using compressed air.
- Squeeze plastic tabs of
male end connector.
- Pull connection apart.
Repeat for the other fitting.
- Wipe off the male pipe end using a clean shop towel.
- Clean or replace components/assemblies as required.
Installation Procedure
Caution: In order to reduce the risk of fire and personal injury, before connecting
fuel pipe fittings, always apply a few drops of clean engine oil to the male
pipe ends.
This will ensure proper reconnection and prevent a possible fuel leak.
During normal operation, the O-rings located in the female connector
will swell and may prevent proper reconnection if not lubricated.
- Apply a few drops of clean oil to the male pipe end.
- Push both sides of the quick-connect fitting together in order to cause
the retaining tabs/fingers to make sure snap into place.
- Pull on both sides of the quick connect fitting in order to make sure
the connection is secure.
- Tighten the fuel fill cap.
- Reconnect the negative battery cable. Refer to
Battery Negative Cable Disconnection and Connection
in engine
electrical.
5.1. | Turn the ignition ON for 2 seconds. |
5.2. | Turn the ignition Off for 10 seconds. |
5.3. | Turn the ignition ON . |
5.4. | Check for fuel leaks. |
- Reinstall the fuel injection sight shield. Refer to
Fuel Injector Sight Shield Replacement
in
engine mechanical.