Step | Action | Value(s) | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
1 | Inspect the instrument panel lamp bulb filament. Refer to Instrument Panel Compartment Lamp Replacement in Instrument Panel, Guages and Console. Is the instrument panel lamp bulb filament open? | -- | Go to Step 8 | Go to Step 2 | ||||
2 | Inspect fuse 28 in the fuse block. Is fuse 28 open? | -- | Go to Step 7 | Go to Step 3 | ||||
3 |
Did the test light illuminate? | -- | Go to Step 4 | Go to Step 10 | ||||
4 | Use a test lamp in order to probe between the instrument panel lamp bulb socket terminals A and B. Did the test light illuminate? | -- | Go to Step 11 | Go to Step 5 | ||||
5 | Use a test lamp in order to backprobe between B+ and the instrument panel lamp switch terminal B. Did the test light illuminate? | -- | Go to Step 6 | Go to Step 12 | ||||
6 |
Did the instrument panel light illuminate? | -- | Go to Step 13 | Go to Step 14 | ||||
7 |
Is fuse 28 open again? | -- | Go to Step 9 | Go to Step 15 | ||||
8 | Replace the instrument panel lamp bulb. Has the repair been made? | -- | Go to Step 15 | -- | ||||
9 | Repair the short to ground in CKT 240. Has the repair been made? | -- | Go to Step 15 | -- | ||||
10 | Repair the following conditions in CKT 240:
Has the repair been made? | -- | Go to Step 15 | -- | ||||
11 |
Has the repair been made? | -- | Go to Step 15 | -- | ||||
12 | Repair the following conditions in CKT 150:
Has the repair been made? | -- | Go to Step 15 | -- | ||||
13 |
Has the repair been made? | -- | Go to Step 15 | -- | ||||
14 | Repair the following conditions in CKT 175:
Has the repair been made? | -- | Go to Step 15 | -- | ||||
15 |
Have all repairs been made? | -- | Refer to Interior Lamps System Check | -- |