Step | Action | Yes | No |
---|---|---|---|
1 | Was the Lighting Systems Diagnostic System Check Performed? | Go to Step 2 | Go to A Diagnostic System Check - Lighting Systems |
2 | Inspect the instrument panel compartment lamp. Is the lamp filiment open? | Go to Step 9 | Go to Step 3 |
3 |
Does the testlamp light? | Go to Step 4 | Go to Step 6 |
4 | Use a testlamp connected to battery positive voltage in order to test for ground at terminal B of the instrument panel compartment lamp/switch connector. Does the testlamp light? | Go to Step 5 | Go to Step 8 |
5 | Inspect for poor connections at the instrument panel compartment lamp/switch connector. Refer to Testing for Intermittent and Poor Connections and Connector Repairs in Wiring Systems. Was a condition found and corrected? | System OK | Go to Step 7 |
6 | Repair the open in CKT 1732 between the lamp/switch connector and splice S222. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | System OK | -- |
7 | Replace the instrument panel compartment lamp/switch assembly. Refer to Instrument Panel Compartment Lamp Replacement. Did you complete the repair? | System OK | -- |
8 | Repair the open in the ground CKT 150. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | System OK | -- |
9 | Replace the instrument panel compartment lamp. Did you complete the replacement? | System OK | -- |