Removal Procedure
- Remove the hose clamps.
- Remove the check valve
and hose (8) from the booster (1) and the vacuum pipe.
Installation Procedure
Important: Install the check valve and hose in the proper direction as indicated
on the hose. Improper hose installation will cause the check valve to stop
the vacuum flow to the booster assembly, rendering the booster assembly inoperative.
- Install the check valve and hose (8) to the booster (1) and the vacuum
pipe.
- Secure the check valve and hose (8) with hose clamps.