Step | Action | Value(s) | Yes | No | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Was the Functional Test performed? | -- | Go to Step 2 | Go to Function Test | ||||||||
2 |
Is the airflow correct? | -- | Go to Step 3 | Go to Step 8 | ||||||||
3 |
Does air flow through the vent outlets at ambient temperature and no air flow through the heater, defroster and side window defroster outlets? | -- | Go to Step 4 | Go to Step 8 | ||||||||
4 |
Is the airflow correct? | -- | Go to Step 5 | Go to Step 8 | ||||||||
5 |
Is the airflow correct? | -- | Go to Step 6 | Go to Step 8 | ||||||||
6 |
Are the door travel and effort correct? | -- | Go to Step 7 | Go to Step 9 | ||||||||
7 | Test the control cable(s) travel by moving the corresponding control at the heater control unit. Is the control cable travel correct? | -- | Go to Step 10 | Go to Step 11 | ||||||||
8 | Repair the affected control cable(s) as necessary. Refer to the following:
Is the action complete? | -- | Go to Step 12 | -- | ||||||||
9 | Repair the affected door at the heater case as necessary. Is the action complete? | -- | Go to Step 12 | -- | ||||||||
10 | Reinstall the control cable(s). Is the action complete? | -- | Go to Step 12 | -- | ||||||||
11 | Inspect the control cable(s) attachment at the heater control unit. Repair any control cable attachment as necessary. Is the action complete? | -- | Go to Step 12 | -- | ||||||||
12 | Perform the Function Test . Is the action complete? | -- | System OK | -- |