Step | Action | Values | Yes | No | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics DEFINITION: Air does not flow correctly from the air distribution outlets. | ||||||||||||||||||
1 | Did you review the HVAC operation and perform the necessary inspections? | -- | Go to Step 2 | |||||||||||||||
2 |
Is the blower motor OFF? | -- | Go to Step 3 | Go to Blower Motor Always On | ||||||||||||||
3 | Place the blower motor switch in each speed position. Does the blower motor operate in any of the speed positions? | -- | Go to Step 4 | Go to Blower Motor Inoperative | ||||||||||||||
4 | Does the blower motor operate in each speed position? | -- | Go to Step 5 | Go to Blower Motor Malfunction | ||||||||||||||
5 |
Does the recirculation actuator operate? | -- | Go to Step 6 | |||||||||||||||
6 | Operate the mode switches through each mode position. Does air flow from the correct air distribution outlets? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 7 | ||||||||||||||
7 | Inspect the mode door and the mode actuator for the following conditions:
Did you find and correct the condition? | -- | Go to Step 21 | Go to Step 8 | ||||||||||||||
8 |
Does the mode actuator shaft rotate? | -- | Go to Step 15 | Go to Step 9 | ||||||||||||||
9 |
Do the voltages measure within the specified range? | 6-8 V | Go to Step 11 | Go to Step 10 | ||||||||||||||
10 | Test the applicable mode door position signal circuit of the mode actuator for an open, short to ground or short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 21 | Go to Step 18 | ||||||||||||||
11 | Test the ground circuit of the mode actuator for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 21 | Go to Step 12 | ||||||||||||||
12 | Test the mode door control A circuit and the mode door control B circuit of the mode actuator for an open, high resistance, short to ground or short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 21 | Go to Step 13 | ||||||||||||||
13 |
Does the mode actuator shaft rotate? | -- | Go to Step 18 | Go to Step 14 | ||||||||||||||
14 |
Does the mode actuator shaft rotate? | -- | Go to Step 18 | Go to Step 17 | ||||||||||||||
15 |
Do the voltages measure within the specified range? | 6-8 V | Go to Step 17 | Go to Step 16 | ||||||||||||||
16 | Test the applicable mode door position signal circuit of the mode actuator for an open, short to ground or short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 21 | Go to Step 18 | ||||||||||||||
17 | Inspect for poor connections at the harness connector of the mode actuator. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 21 | Go to Step 19 | ||||||||||||||
18 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 21 | Go to Step 20 | ||||||||||||||
19 | Replace the mode actuator. Refer to Mode Actuator Replacement . Did you complete the replacement? | -- | Go to Step 21 | -- | ||||||||||||||
20 | Replace the HVAC control module. Refer to HVAC Control Module Replacement . Did you complete the replacement? | -- | Go to Step 21 | -- | ||||||||||||||
21 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 7 |