Removal Procedure
- Disconnect the negative battery cable. Refer to Battery Disconnect
Caution in Cautions and Notices.
- Remove the electrical
connector bolt from EBCM.
- Disconnect the electrical connector from EBCM.
- Remove the four bolts (2) and four washers (3) and remove the
EBCM from the bracket.
Installation Procedure
- Install EBCM (1) to bracket.
- Install the four EBCM mounting bolts (2) and washers (3).
- Connect the EBCM electrical connector.
- Install the EBCM electrical connector bolt.
Tighten
Tighten the EBCM electrical connector bolt to 2 N·m (18 lb in)
- Connect the negative battery cable. Refer to Battery Disconnect
Caution in Cautions and Notices.
- Return to A Diagnostic System Check.