Step | Action | Value(s) | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|---|
1 | Place the blower speed switch in the failing speed position. Is MED speed the failing speed? | -- | Go to Step 2 | Go to Step 3 | ||||||
2 | Locate and repair the open in CKT 192 (BLU/RED) between the blower resistor and the HVAC mode switch. Is the repair complete? | -- | System OK | Go to Step 3 | ||||||
3 |
Does the DMM indicate continuity? | -- | Go to Step 4 | Go to Step 5 | ||||||
4 | Replace the blower motor resistor. Refer to Blower Motor Resistor Replacement . Is the repair complete? | -- | System OK | Go to Step 5 | ||||||
5 |
Does the test lamp light? | -- | Go to Step 6 | Go to Step 7 | ||||||
6 | Locate and repair the open in the wire between the blower resistor and the A/C mode switch. Is the repair complete? | -- | System OK | Go to Step 7 | ||||||
7 | Replace the A/C mode switch. Refer to Control Assembly Replacement . Is the repair complete? | -- | System OK | -- |