- Inspect the circuit breaker and determine the condition. If the
circuit breaker is open, locate and repair the cause of the overload and replace
the circuit breaker.
- Inspect G405 to make certain that it is clean and tight.
- If a single lamp does not illuminate, inspect the lamp for an
open filament. Replace the lamp if required. Also inspect the lamp socket
for corrosion. Clean the socket if required.
- Adjust or replace the backup lamp switch if the lamps do not turn
off.
- Inspect for a broken (or partially broken) conductor inside the
insulation which could cause a malfunction but prove GOOD in a system test
for continuity or voltage. These circuits may be intermittent or resistive,
when loaded, and if possible, should be monitored for a voltage drop when
the system is placed under load.
- Inspect for proper installation of aftermarket electronic equipment
which might affect the operation of other equipment.