System Description
The horn system consists of the following components:
System Operation
The vehicle horn system is activated under the following conditions:
• | The horn switch is depressed. |
Circuit Operation
Battery positive voltage is applied at all times to the horn relay coil
and the horn relay switch. Pressing the horn switch applies ground to the
horn relay control circuit. The BCM may also apply ground to the horn relay
control circuit as described above. When the horn relay control circuit
is grounded, the horn relay is energized and battery positive voltage is
applied to the horns through the horn control circuit. The horns sound
as long as ground is applied to the horn relay control circuit.