Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
Important: A short to ground will cause an open fuse(s). Before performing this diagnostic procedure, inspect the fuse(s) for an open. | ||||
1 |
Is the resistance measured within the specified range? | 0-2 ohms | Go to Step 2 | Go to Step 3 |
2 | Use a DMM in order to measure the voltage between terminal C of the dome and rear view mirror reading lamps connector and ground. Is the voltage measured equal to the specified value? | B+ | Go to Step 4 | Go to Step 8 |
3 | Repair the open in CKT 750 between the dome and rear view mirror reading lamps and ground splice pack G401. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
4 | Use a DMM in order to measure the resistance between terminal A of the dome and rear view mirror reading lamps connector and ground. Is the resistance measured within the specified range? | 0-2 ohms | Go to Step 5 | Go to Step 6 |
5 | Replace the rear view mirror reading lamps. Is the repair complete? | -- | -- | |
6 |
Is the resistance measured within the specified range? | 0-2 ohms | Go to Step 7 | Go to Step 10 |
7 | Repair the open in CKT 156 between the left IP junction block and the dome and rear view mirror reading lamps. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
8 | Use a DMM in order to backprobe the left IP junction block connector C3 and measure the voltage between terminal C4 and ground. Is the voltage measured equal to the specified value? | B+ | Go to Step 9 | Go to Step 10 |
9 | Repair the open in CKT 1732 between the left IP junction block and the dome and rearview mirror reading lamps. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
10 | Replace the left IP junction block. Is the repair complete? | -- | -- |