Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
Important: A short to ground will cause an open fuse(s). Before performing this diagnostic procedure, inspect the fuse(s) for an open. | ||||
1 |
Is the voltage measured equal to the specified value? | 0 V | Go to Step 2 | Go to Step 3 |
2 |
Is the resistance measured within the specified range? | 0-2 ohms | Go to Step 4 | Go to Step 7 |
3 | Repair the short to positive battery voltage in CKT 395 between the right IP junction block connector C3 terminal B11 and the right rear door jamb switch connector terminal B. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
4 | Use a DMM in order to measure the resistance in CKT 650 between the right rear door jamb switch connector terminal A and ground. Is the resistance measured within the specified range? | 0-2 ohms | Go to Step 5 | Go to Step 8 |
5 | Use a DMM in order to measure the resistance between the right rear door jamb switch connector terminal A and terminal B. Is the resistance equal to the specified value? | ∞ | Go to Step 6 | |
6 | Replace the right rear door jamb switch. Is the repair complete? | -- | -- | |
7 | Repair the open in CKT 395 between the right rear door jamb switch connector terminal B and the right IP junction block connector C3 terminal B11. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
8 | Repair the open in CKT 650 between the right rear door jamb switch connector terminal A and ground splice pack G302. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- |