When you first turn the ignition switch to the RUN position, the inflatable restraint sensing and diagnostic module (SDM) performs tests in order to diagnose critical malfunctions within the module. The SDM measures the ignition positive voltage, the 23 VLR and the deployment loop voltages in order to ensure that the voltages are within the respective normal voltage ranges. The SDM proceeds to continuous monitoring. The SDM contains a resistor network connected to 5 volts, ground, and to the SDM front end sensor signal terminal 9. The 1.0 K ohms resistor in the inflatable restraint front end discriminating sensor parallel to the normally open switch provides a parallel path to ground. This causes a specified percentage of voltage to appear at the SDM front end sensor signal input. The SDM monitors this voltage to detect shorts to power or an open discriminating sensor.
• | The SDM is configured for an inflatable restraint front end discriminating sensor. |
• | The voltage at the front end sensor signal terminal 9 is more than 5.0 volts for 500 milliseconds. |
The continuous monitoring test inspects for this DTC. This test occurs when the ignition positive voltage is within the normal operating voltage range.
• | The SDM sets a diagnostic trouble code. |
• | The SDM turns ON the AIR BAG Warning Indicator. |
• | Current DTC |
The voltage at front end sensor signal terminal 9 is less than 3.2 volts for 500 milliseconds. |
• | History DTC |
- | You issue a scan tool CLEAR CODES command. |
- | 250 malfunction free ignition cycles have occurred. |
A broken or chafed wire in the inflatable restraint front end discriminating sensor circuit may cause an intermittent condition. Inspect CKT 1834 and CKT 1751 carefully for cut or chafed wires.
When measurements are requested in this table, use J 39200 Digital Multimeter with the correct terminal adapter from J 35616 Connector Test Adapter Kit. When a check for proper connection is requested, refer to Intermittents and Poor Connections . When a wire, connector or terminal repair is requested, use J-38125 Terminal Repair Kit and refer to Wiring Repair .
The numbers below refer to the step numbers on the diagnostic table:
This test checks for proper contact or corrosion of the yellow 2-way connector.
This test checks for a malfunctioning discriminating sensor.
This test checks for an open in CKT 1751.
This test checks for proper contact or corrosion of the inflatable restraint Sensing and Diagnostic Module (SDM) connector.
This test checks for an open in CKT 1834.
This test checks for a short to voltage in CKT 1834.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the SIR Diagnostic System Check performed? | -- | ||
Are the terminals damaged or corroded? | -- | |||
3 | Replace the sensor harness connector. Refer to Wiring Repair . Is the repair complete? | -- | -- | |
4 | Check for proper connection at the sensor connector terminals A and B. Are the terminals damaged or corroded? | -- | ||
5 | Check for proper connection at the sensor connector terminals A and B. Are the terminals damaged or corroded? | -- | ||
6 | Replace the inflatable restraint front end discriminating sensor. Refer to Inflatable Restraint Front End Discriminating Sensor Replacement . Is the repair complete? | -- | -- | |
Using J 39200 DMM, measure the resistance between the sensor connector terminals A and B. Is the resistance reading more than the specified value? | 1050 ohms | |||
Using J 39200 DMM, measure the resistance from the sensor harness connector terminal B to ground. Is the resistance reading within the specified values? | 0-5 ohms | |||
9 | Repair an open condition in CKT 1751. Is the repair complete? | -- | -- | |
Is the connector damaged or corroded? | -- | |||
11 | Replace the SDM harness connector. Refer to Connector Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
12 | Check for proper connection at terminal 9 of the SDM. Is the terminal damaged or corroded? | -- | ||
13 | Check for proper connection at terminal 9 of the SDM. Is the terminal damaged or corroded? | -- | ||
14 | Replace the inflatable restraint Sensing and Diagnostic Module (SDM). Refer to Inflatable Restraint Sensing and Diagnostic Module Replacement . Are the repairs complete? | -- | -- | |
Using J 39200 DMM, measure the resistance between the sensor harness connector terminal A and the SDM harness connector terminal 9. Is the resistance reading within the specified values? | 0-5 ohms | |||
16 | Repair an open condition in CKT 1834. Is the repair complete? | -- | -- | |
Is the measured voltage less than the specified value? | 1.0 V | |||
18 |
Is the repair complete? | -- | -- | |
19 | Reconnect all the SIR system components, make sure all the components are properly mounted. Have all the SIR components been reconnected and properly mounted? | -- | -- | |