Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Data Link Communications System Check? | -- | Go to Step 2 | |
2 |
Does the scan tool communicate with the Class 2 serial data line? | -- | Go to Step 4 | Go to Step 3 |
3 | The scan tool may be malfunctioning. Refer to the scan tool instruction manual in order to ensure that the scan tool is functioning. Does the scan tool operate properly? | -- | -- | |
4 |
Is the terminal contact between the data link connector (DLC) terminal 2 and the scan tool OK? | -- | Go to Step 6 | Go to Step 5 |
5 | Repair the terminal contact between the DLC and the scan tool. Did you complete the repair? | -- | -- | |
6 |
Does the scan tool communicate with the RFA module? | -- | Go to Step 7 | Go to Step 8 |
7 | Replace the PCM. Did you complete the repair? | -- | -- | |
8 |
Did you find the condition? | -- | Go to Step 9 | Go to Step 10 |
9 | Repair the open or short in CKT 1807 (PPL). Did you complete the repair? | -- | -- | |
10 | Replace the RFA module. Did you complete the repair? | -- | -- |