Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 |
Does the scan tool communicate with instrument cluster? | -- | Go to Step 2 | Go to Step 3 |
2 | Test the instrument cluster for DTC's. Are any DTC's stored? | -- | System OK | |
3 | Attempt to communicate with the other systems connected to the same serial data line. Does the scan tool communicate with the other systems? | -- | Go to Step 4 | |
4 |
Is the voltage within the specified range? | 10-15 V | Go to Step 6 | Go to Step 5 |
5 | Repair the open or short to ground. Refer to Wiring Repairs . Is the repair complete? | -- | Go to Step 9 | -- |
6 | Measure the voltage between terminal D15 (Oldsmobile) or terminals F14 and E14 (Buick) and ground terminals D12 and C12 (Oldsmobile) and F12 and E12 (Buick). Is the voltage within the specified range? | 10-15 V | Go to Step 8 | Go to Step 7 |
7 | Repair the open. Refer to Wiring Repairs . Is the repair complete? | -- | Go to Step 9 | -- |
8 | Replace the instrument cluster. Refer to Instrument Cluster Replacement . Is the replacement complete? | -- | Go to Step 9 | -- |
9 |
Are all of the DTC's cleared? | -- | System OK | -- |