Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Perform the Audible Warnings System Check before processing. Is the system check complete? | -- | Go to Step 2 | |
2 |
Is the measured resistance less than the specified value? | 5 ohms | Go to Step 4 | Go to Step 3 |
3 | Replace the mall module. Is the repair complete? | -- | -- | |
4 | Does the keyless entry work? | -- | Go to Step 5 | Go to Keyless Entry for Diagnosis |
5 | Inspect CKT 653 (DK BLU/WHT) for an open. Is the circuit OK? | -- | Go to Step 10 | Go to Step 6 |
6 |
Is the measured resistance less than the specified value? | 5 ohms | Go to Step 9 | Go to Step 7 |
7 | Inspect the RFA module connector for proper terminal contact. Is the contact OK? | -- | Go to Step 8 | -- |
8 | Replace the RFA module. Is the repair complete? | -- | -- | |
9 |
Is the wiring OK? | -- | Go to Step 10 | |
10 | Repair the open. Is the repair complete? | -- | -- |