Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Perform the Instrument Cluster System Check. Is the system check complete? | -- | Go to Step 2 | |
2 |
Does the voltage equal the specified values? | 12 V | Go to Step 4 | Go to Step 3 |
3 | Inspect CKT 390 (YEL) for an open or short to ground. Is the wiring OK? | -- | -- | |
4 |
Does the voltage vary with the dimmer control? | -- | Go to Step 6 | Go to Step 5 |
5 |
Does the voltage vary with the dimmer control? | -- | Go to Step 8 | Go to Interior Lights: Dimming |
6 | Inspect the instrument cluster connector C1 terminal F4 and terminal F5 for proper terminal contact. Is the contact OK? | -- | Go to Step 7 | -- |
7 | Replace the instrument cluster. Is the repair complete? | -- | -- | |
8 | Inspect CKT 8 (GRY) for an open or short to ground. Is the circuit OK? | -- | Go to Step 9 | |
9 | Repair the wiring. Is the repair complete? | -- | -- |
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Perform the Instrument Cluster System Check. Is the system check complete? | -- | Go to Step 2 | |
2 |
Does the voltage equal the specified values? | 12 V | Go to Step 4 | Go to Step 3 |
3 | Inspect CKT 390 (YEL) for an open or short to ground. Is the wiring OK? | -- | -- | |
4
|
Does the voltage vary with the dimmer control? | -- | Go to Step 6 | Go to Step 5 |
5 |
Does the voltage vary with the dimmer control? | -- | Go to Step 8 | Go to Interior Lights: Dimming |
6 | Inspect the instrument cluster connector C1 terminal C7 and terminal D11 for proper terminal contact. Is the contact OK? | -- | Go to Step 7 | -- |
7 | Replace the instrument cluster. Is the repair complete? | -- | -- | |
8 | Inspect CKT 1244 (BRN) for an open or short to ground. Is the circuit OK? | -- | Go to Step 9 | |
9 | Repair the wiring. Is the repair complete? | -- | -- |