Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Perform the Audible Warnings System Check before processing. Is the system check complete? | -- | Go to Step 2 | |
2 |
Does the measured voltage match the specified value? | 12 V | Go to Step 4 | Go to Step 3 |
3 |
Are the circuits OK? | -- | Go to Power Distribution for Diagnosis | Go to Step 10 |
4 |
Does the measured voltage match the specified value? | 12 V | Go to Step 6 | Go to Step 5 |
5 |
Are the circuits OK? | -- | Go to Power Distribution for Diagnosis | Go to Step 10 |
6 |
Does the measured voltage match the specified value? | 12 V | Go to Step 8 | Go to Step 7 |
7 | Inspect CKT 150 (BLK) for an open. Is the circuit OK? | -- | Go to Step 10 | |
8 |
Does the measured voltage match the specified value? | 12 V | Go to Step 11 | Go to Step 9 |
9 |
Are the circuits OK? | -- | Go to Power Distribution for Diagnosis | Go to Step 10 |
10 | Repair the open or short to ground. Is the repair complete? | -- | -- | |
11 | Inspect the mall module connectors for proper terminal contact. Is the contact OK? | -- | Go to Step 12 | -- |
12 | Replace the mall module. Is the repair complete? | -- | -- |