Step
| Action
| Value(s)
| Yes
| No
|
1
|
- Disconnect the fuel door release switch.
- Connect a test lamp between fuel door release switch connector
terminal A and ground.
Does the test lamp light?
| --
|
Go to Step
2
|
Go to Step 3
|
2
|
- Test the F/DR REL fuse.
- If OK, repair the open or short to ground in CKT 740, ORN.
Is the symptom still present?
| --
|
Go to Step
3
| Go to
Fuel Filler Door Release System Check
|
3
| Connect a test lamp between fuel door release switch connector
terminal A and terminal B.
Does the test lamp light?
| --
|
Go to Step
4
|
Go to Step 5
|
4
|
- Inspect for proper terminal contact at the fuel door release switch
connector.
- If OK, replace the fuel door release switch.
Is the symptom still present?
| --
|
Go to Step
5
| Go to
Fuel Filler Door Release System Check
|
5
|
- Disconnect the fuel door release actuator connector.
- Connect a test lamp between actuator connector terminal B
and ground.
- Install the fuel door release switch.
- Activate the switch.
Does the test lamp light?
| --
|
Go to Step
6
|
Go to Step 7
|
6
|
- Connect a test lamp between the fuel door release actuator terminals
A and B.
- Activate the fuel door release switch.
Does the test lamp light?
| --
|
Go to Step
8
|
Go to Step 9
|
7
| Test for an open in CKT 79, PNK.
Is the repair complete?
| --
| Go to
Fuel Filler Door Release System Check
| --
|
8
|
- Inspect for proper terminal contact at the fuel door release actuator
connector.
- If OK, replace the fuel door release actuator.
Is the repair complete?
| --
| Go to
Fuel Filler Door Release System Check
| --
|
9
|
- Inspect ground G302 for proper terminal contact.
- If OK, repair open in CKT 1050 (BLK).
Is the repair complete?
| --
| Go to
Fuel Filler Door Release System Check
| --
|
Step
| Action
| Value(s)
| Yes
| No
|
1
|
- Disconnect the release switch connector.
- Connect a test lamp between release switch connector terminal A
and ground.
Does the test lamp light?
| --
|
Go to Step
3
|
Go to Step 2
|
2
|
- Test the F/DR fuse.
- Test for an open or short to ground in CKT 840, ORN.
Is the symptom still present?
| --
|
Go to Step
3
| Go to
Fuel Filler Door Release System Check
|
3
| Connect
a test lamp between release switch connector terminal A and terminal B.
Does the test lamp light?
| --
|
Go to Step
4
|
Go to Step 5
|
4
|
- Inspect for proper terminal contact at the release switch connector.
- If OK, replace release switch.
Is the symptom still present?
| --
|
Go to Step
5
| Go to
Fuel Filler Door Release System Check
|
5
|
- Disconnect the fuel door release actuator connector.
- Connect a fused jumper between release switch connector terminal A
and terminal B.
- Connect a test lamp between actuator connector terminal B
and ground.
Does the test lamp light?
| --
|
Go to Step
6
|
Go to Step 7
|
6
|
- Test for an open in CKT 1050, BLK.
- Inspect ground G302 for proper terminal contact.
- Inspect for proper terminal contact at the fuel door release actuator
connector.
- If OK, replace the fuel door release actuator.
Is the repair complete?
| --
| Go to
Fuel Filler Door Release System Check
| --
|
7
| Test for an open in CKT 79, PNK.
Is the repair complete?
| --
| Go to
Fuel Filler Door Release System Check
| --
|