Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 |
Does either zone indicate on? | -- | Go to Step 2 | Go to Step 3 |
2 |
Does the scan tool indicate rear defog Zone 1 or 2 on? | -- | Go to Step 6 | Go to Step 10 |
3 |
Does the test lamp light? | -- | Go to Step 4 | Go to Step 7 |
4 |
Does the test lamp light? | -- | Go to Step 5 | Go to Step 6 |
5 | Repair the short to ground in circuit 1777 (RED) or circuit 193 (WHT). Has the repair been made and the system rechecked? | -- | Go to Defogger System Check | -- |
6 | Replace the HVAC programmer. Refer to Programmer Replacement in HVAC. Has the repair been made and the system rechecked? | -- | Go to Defogger System Check | -- |
7 |
Does the test lamp light? | -- | Go to Step 8 | Go to Step 9 |
8 | Repair a short to voltage in circuit 293 (PPL) relay 2. Has the repair been made and the system rechecked? | -- | Go to Defogger System Check | -- |
9 | Replace the suspect relay. Has the repair been made and the system rechecked? | -- | Go to Defogger System Check | -- |
10 | Replace the HVAC control assembly. Refer to Control Assembly Replacement - Passenger in HVAC. Has the repair been made and the system rechecked? | -- | Go to Defogger System Check | -- |