The EVAP Fuel Tank Pressure sensor is a sensor that changes resistance based upon fuel tank pressure (or vacuum). A vacuum is considered negative pressure.
The PCM provides a 5 volt reference and ground. The EVAP Fuel Tank Pressure sensor signal varies between ground and 5 volts as fuel tank pressure varies. As pressure decreases (negative pressure, or vacuum), voltage increases. As pressure increases, voltage decreases (positive pressure, low voltage). The PCM uses the EVAP Fuel Tank Pressure sensor values as an indicator of EVAP system efficiency. If the EVAP Fuel Tank Pressure sensor signal goes high such as when the signal line is shorted to voltage or the EVAP Fuel Tank Pressure sensor is shorted internally, this DTC will set.
• | DTC P0601 is not set. |
• | Fuel level at engine start up is the same or less than 85% full. |
• | The Intake Air Temperature (IAT) at engine start up is between 2°C and 60°C. |
The EVAP Pressure sensor reading has been 4.80 volts or higher.
PCM disables Evaporative Emission (EVAP) control solenoid.
• | The PCM will illuminate the Malfunction Indicator Lamp (MIL) when the diagnostic runs and fails. |
• | The PCM will record operating conditions at the time the diagnostic fails. This information will be stored in the Freeze Frame and Failure Records. |
• | The PCM will turn the MIL OFF after three consecutive drive trips that the diagnostic runs and does not fail. |
• | A Last Test Failed (current) DTC will clear when the diagnostic runs and does not fail. |
• | A History DTC will clear after forty consecutive warm-up cycles with no failures of any emission related diagnostic test. |
• | Use a scan tool to clear DTCs. |
• | Interrupting PCM battery voltage may or may not clear DTCs. This practice is not recommended. Refer to Clearing Diagnostic Trouble Codes in Powertrain Control Module Description . |
The EVAP Fuel Tank Pressure Sensor monitors a range from 7.5 in. H2O of pressure to -17.5 in. H2O of pressure (vacuum).
The vacuum and pressure in the EVAP system is measured in inches of H2O (water). Most gauges measure vacuum in inches of Hg (mercury) and pressure in psi (pounds per square inch). The following shows how the values compare:
in. H2O | in. Hg. | psi |
---|---|---|
1 in. H2O | 0.07 in. Hg | 0.0361 psi. |
5 in. H2O | 0.36 in. Hg | 0.180 psi. |
10 in. H2O | 0.73 in. Hg | 0.361 psi. |
15 in. H2O | 1.10 in. Hg | 0.541 psi. |
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Powertrain On-Board Diagnostic (OBD) System Check? | -- | Refer to Diagnostic Aids |