DDM -- Data Display -- Pass. HVAC Switch: The scan tool displays 0 to 255 counts. This indicates the
passenger climate control selection.
DIM -- A/C Information -- A/C Clutch (actual): The scan tool displays On or Off. On is displayed when the PCM
has energized the A/C clutch relay.
DIM -- A/C Information -- A/C Clutch (desired): The scan tool displays On or Off. On is displayed when the IPM
is requesting A/C system operation and the DIM has determined that none of
the system performance limits are exceeded.
DIM-- A/C Information --A/C Orifice Relay: The scan tool displays Active or Inactive. Active is displayed
when the orifice tube relay is energized by the DIM increasing the orifice
diameter and lowering A/C high side pressure.
DIM -- A/C Information -- A/C Pressure: The scan tool displays 0 to 4000 kPa (0 to 580 psi).
The output of the A/C pressure sensor provided by the PCM over the Class 2
communication link.
DIM -- A/C Information -- Clutch Voltage: The scan tool displays Low or Normal. Low is displayed when the
battery voltage is low, such that clutch slippage is possible.
DIM -- A/C Information -- Control Head (desired): The scan tool displays A/C On or A/C Off. A/C On is displayed when
the IPM is requesting A/C system operation.
DIM -- A/C Information -- Evaporator Temp.: The scan tool displays -40 to +215°C (-40
to +420°F). The output of the A/C low side thermistor.
DIM -- A/C Information -- Evaporator Temp Status: The scan tool displays OK or Cold. Cold is displayed when evaporator
temperature drops below 5°C (41°F).
DIM -- A/C Information -- Pressure Status: The scan tool displays Low, Normal or High. Normal must be displayed
to allow A/C operation.
DIM -- A/C Information -- Temperature Status: The scan tool displays Hot or OK. Hot is displayed when engine
coolant temperature rises above 121°C (250°F). OK must be displayed
to allow A/C operation.
DIM -- Inputs -- Steering Wheel Controls: The scan tool displays counts. A count number is shown for each
steering wheel command.
DIM -- Output Control-- A/C Orifice Relay: The scan tool displays On or Off. The scan tool will command the
A/C orifice relay On or Off.
IPM -- HVAC Door Calibrations -- Max Air Inlet Dr Pos: The scan tool displays 0 to 255 counts (0 to 5 volts).
The maximum travel range when driven to the stop during Recalibrate all Motors
command.
IPM -- HVAC Door Calibrations -- Max Htr./Def./A/C Dr. Pos.: The scan tool displays 0 to 255 counts (0 to 5 volts).
The maximum travel range when driven to the stop during Recalibrate all Motors
command.
IPM -- HVAC Door Calibrations -- Max Left Temp Dr Pos: The scan tool displays 0 to 255 counts (0 to 5 volts).
The maximum travel range when driven to the stop during Recalibrate all Motors
command.
IPM -- HVAC Door Calibrations -- Max Right Temp Dr Pos: The scan tool displays 0 to 255 counts (0 to 5 volts).
The maximum travel range when driven to the stop during Recalibrate all Motors
command.
IPM -- HVAC Door Calibrations -- Min Air Inlet Dr Pos: The scan tool displays 0 to 255 counts (0 to 5 volts).
The minimum travel range when driven to the stop during Recalibrate all Motors
command.
IPM -- HVAC Door Calibrations -- Min Htr./Def./A/C Dr. Pos.: The scan tool displays 0 to 255 counts (0 to 5 volts).
The minimum travel range when driven to the stop during Recalibrate all Motors
command.
IPM -- HVAC Door Calibrations -- Min Left Temp Dr Pos: The scan tool displays 0 to 255 counts (0 to 5 volts).
The minimum travel range when driven to the stop during Recalibrate all Motors
command.
IPM -- HVAC Door Calibrations -- Min Right Temp Dr Pos: The scan tool displays 0 to 255 counts (0 to 5 volts).
The minimum travel range when driven to the stop during Recalibrate all Motors
command.
IPM -- HVAC Door Positions -- Air Inlet Dr Actual: The scan tool displays 0 to 255 counts (0 to 5 volts).
The signal output from the feedback pot on the actuator.
IPM -- HVAC Door Positions -- Air Inlet Dr Commanded: The scan tool displays 0 to 255 counts (0 to 5 volts).
The desired position of the actuator.
IPM -- HVAC Door Positions -- Htr./Def./A/C Dr Actual: The scan tool displays 0 to 255 counts (0 to 5 volts).
The signal output from the feedback pot on the actuator.
IPM -- HVAC Door Positions -- Htr./Def./A/C Dr Commanded: The scan tool displays 0 to 255 counts (0 to 5 volts).
The desired position of the actuator.
IPM -- HVAC Door Positions -- Left Temp Dr. Actual: The scan tool displays 0 to 255 counts (0 to 5 volts).
The signal output from the feedback pot on the actuator.
IPM -- HVAC Door Positions -- Left Temp. Dr. Commanded: The scan tool displays 0 to 255 counts (0 to 5 volts).
The desired position of the actuator.
IPM -- HVAC Door Positions -- Right Temp Dr Actual: The scan tool displays 0 to 255 counts (0 to 5 volts).
The signal output from the feedback pot on the actuator.
IPM -- HVAC Door Positions -- Right Temp. Dr. Commanded: The scan tool displays 0 to 255 counts (0 to 5 volts).
The desired position of the actuator.
IPM -- HVAC Motors -- Air Inlet Door Position: The scan tool displays Outside or Recirc. Shows the current position
of the air inlet door.
IPM -- HVAC Motors -- Htr./Def./A/C Door Position: The scan tool displays Defrost or A/C. Shows the current position
of the htr./def./A/C door.
IPM -- HVAC Motors -- Left Temp. Door Position: The scan tool displays Defrost, Hot or Cold. Shows the current
position of the left temperature door.
IPM -- HVAC Motors -- Right Temp. Door Position: The scan tool displays Hort or Cold. Shows the current position
of the right temperature door.
IPM -- HVAC Sensors -- Inside Air Temp: The scan tool displays -40 to +60°C (-40
to +140°F). The output of the inside air temperature sensor.
IPM -- HVAC Sensors -- Left AC Duct Temp: The scan tool displays -40 to +150°C (-40
to +300°F). The output of the LH A/C duct temperature sensor.
IPM -- HVAC Sensors -- Left Duct Temp Desired: The scan tool displays -18 to +120°C (0 to +250°F).
The target LH A/C duct temperature that the HVAC system is trying to achieve.
IPM -- HVAC Sensors -- Left Htr. Duct Temp: The scan tool displays -40 to +150°C (-40
to +300°F). The output of the LH HTR duct temperature sensor.
IPM -- HVAC Sensors -- Left Solar: The scan tool displays 0 to 50 counts. The solar load output
of the LH sunload sensor and ambient light sensor.
IPM -- HVAC Sensors -- Outside Air Temp: The scan tool displays -40 to +60°C (-40
to +140°F). The output of the ambient air temperature sensor.
IPM -- HVAC Sensors -- Right AC Duct Temp: The scan tool displays -40 to +150°C (-40
to +300°F). The output of the RH A/C duct temperature sensor.
IPM -- HVAC Sensors -- Right Duct Temp Desired: The scan tool displays -18 to +120°C (0 to +250°F).
The target RH A/C duct temperature that the HVAC system is trying to achieve.
IPM -- HVAC Sensors -- Right Htr. Duct Temp: The scan tool displays -40 to +150°C (-40
to +300°F). The output of the RH HTR duct temperature sensor.
IPM -- HVAC Sensor -- Right Solar: The scan tool displays 0 to 50 counts. The solar load output
of the RH sunload sensor and ambient light sensor.
IPM -- HVAC System Data -- A/C Requested: The scan tool displays Yes or No. The message sent out on class
2 to the DIM when A/C is requested.
IPM -- HVAC System Data -- Commanded Blower: The scan tool displays 0 to 100%.
IPM -- HVAC System Data -- Coolant Temperature: The scan tool displays -40 to +120°C (-40
to +250°F). The information is received from the PCM on the class 2 communication
link.
IPM -- HVAC System Data -- Left Program Number: The scan tool displays 0-255 counts. This value will vary, depending
on the air delivery mode and the air discharge temperature selected by the
driver.
IPM -- HVAC System Data -- Load Reduction Active: The scan tool displays Yes or No. The scan tool shows weather the
HVAC system is disabled.
IPM -- HVAC System Data -- Right Program Number: The scan tool displays 0-255 counts. This value will vary, depending
on the air delivery mode and the air discharge temperature selected by the
passenger.
IPM -- HVAC System Data -- Selected Air Mode: The scan tool displays AUTO, Upper, Defog, Bi-Level, Heater or
Defrost. The current operating mode of the HVAC system.
IPM -- HVAC System Data -- Vehicle Speed: The scan tool displays current vehicle speed.
IPM -- Miscellaneous Tests -- Blower Motor: The scan tool displays On or Off. The status shown is the current
state of the blower motor test as commanded by the scan tool.
IPM -- Miscellaneous Tests -- Display(s) Test: The scan tool displays On or Off. The status shown is the current
state of the displays as commanded by the scan tool.
IPM -- Miscellaneous Tests -- Instant OAT Update: The scan tool displays On. This test updates the OAT on the HVAC
control module as commanded by the scan tool.
IPM -- Miscellaneous Tests -- Recalibrate all Motors: The scan tool displays On. This test recalibrates all the actuators
as commanded by the scan tool.
IPM -- Miscellaneous Tests -- ReLearn Control Panel Type: The scan tool displays the various HVAC options for the vehicle.
This test updates the HVAC system according to the various options for a given
platform as commanded by the scan tool.
IPM -- Open/Short Data -- Inside Air Temp: The scan tool displays 0 to 255 counts (0 to 5 volts).
The status of the sensor signal circuit is monitored. 0 counts indicates a
short to ground, 255 counts indicates an open circuit.
IPM -- Open/Short Data -- Left AC Duct Temp: The scan tool displays 0 to 255 counts (0 to 5 volts).
The status of the sensor signal circuit is monitored. 0 counts indicates a
short to ground, 255 counts indicates an open circuit.
IPM -- Open/Short Data -- Left Htr. Duct Temp.: The scan tool displays 0 to 255 counts (0 to 5 volts).
The status of the sensor signal circuit is monitored. 0 counts indicates a
short to ground, 255 counts indicates an open circuit.
IPM -- Open/Short Data -- Left Solar Sensor: The scan tool displays 0 to 50 counts. The status of the
sensor signal circuit is monitored. 0 counts indicates a short to ground,
255 counts indicates an open circuit.
IPM -- Open/Short Data -- Outside Air Temp: The scan tool displays 0 to 255 counts (0 to 5 volts).
The status of the sensor signal circuit is monitored. 0 counts indicates a
short to ground, 255 counts indicates an open circuit.
IPM -- Open/Short Data -- Right AC Duct Temp: The scan tool displays 0 to 255 counts (0 to 5 volts).
The status of the sensor signal circuit is monitored. 0 counts indicates a
short to ground, 255 counts indicates an open circuit.
IPM -- Open/Short Data -- Right Htr. Duct Temp.: The scan tool displays 0 to 255 counts (0 to 5 volts).
The status of the sensor signal circuit is monitored. 0 counts indicates a
short to ground, 255 counts indicates an open circuit.
IPM -- Open/Short Data -- Right Solar Sensor: The scan tool displays 0 to 50 counts. The status of the
sensor signal circuit is monitored. 0 counts indicates a short to ground,
255 counts indicates an open circuit.
IPM -- Set Options -- Afterblow: The scan tool displays Enable or Disable. The status shown is the
current selection of the afterblow feature.
IPM -- Set Options -- Temperature Offset: The scan tool sets the temperature offset of the right air temperature
switch assembly. Temperatures can be set --5/+5 degrees from the HVAC
control module.
PCM -- Engine Data 1 w/LX5 (V6) -- ECT Sensor: The scan tool displays -40 to +215°C (-40
to +420°F). The output of the engine coolant temperature sensor.
PCM -- Engine Data 2 w/LX5 (V6) -- A/C High Side Pressure: The scan tool displays 0 to 4000 kPa (0 to 580 psi).
The output of the A/C pressure sensor.
PCM -- Engine Data 2 w/LX5 (V6) -- A/C High Side Pressure: The scan tool displays 0 to 5 volts. The output of the A/C
pressure sensor.
PCM -- Engine Data 2 w/LX5 (V6) -- A/C Off for WOT: The scan tool displays Yes or No. Yes is displayed when the PCM
denergizes the A/C CLU relay to reduce engine load during application wide
open throttle.
PCM -- Engine Data 2 w/LX5 (V6) -- A/C Pressure Disable: The scan tool displays Yes or No. Yes is displayed when the system
pressure exceeds 2968 kPa (430 psi).
PCM -- Engine Data 2 w/LX5 (V6) -- A/C Relay Command: The scan tool displays On or Off. On is displayed when the PCM
has energized the A/C clutch relay.
PCM -- Engine Data 2 w/LX5 (V6) -- A/C Request Signal: The scan tool displays Yes or No. Yes is displayed when the DIM
is requesting A/C system operation.
PCM -- Engine Output Controls w/LX5 (V6) -- A/C Relay: The scan tool displays ON or OFF. OFF is displayed when an open
or short is detected in the A/C CLU relay ground circuit.
PCM -- Engine Data 1 w/L47 (V8)-- ECT: The scan tool displays -40 to +215°C (-40 to +420°F).
The output of the engine coolant temperature sensor.
PCM -- Engine Data List 1 w/LX5 (V6) -- A/C Relay Command: The scan tool displays On or Off. On is displayed when the PCM
has energized the A/C clutch relay.
PCM -- Engine Data 2 w/L47 (V8)-- ECT: The scan tool displays -40 to +215°C (-40 to +420°F).
The output of the engine coolant temperature sensor.
PCM -- Engine Data 2 w/L47 (V8) -- A/C Relay Command: The scan tool displays On or Off. On is displayed when the PCM
has energized the A/C clutch relay.
PCM -- Engine Data 3 w/L47 (V8)-- ECT: The scan tool displays -40 to +215°C (-40 to +420°F).
The output of the engine coolant temperature sensor.
PCM -- Engine Data 1 w/L47 (V8)-- A/C Relay Command: The scan tool displays ON or OFF. ON is displayed when the PCM
has energized the A/C clutch relay.
PCM -- Engine Data 2 w/L47 (V8)-- A/C High Side Pressure: The scan tool displays 0 to 4000 kPa (430 psi). The
output of the A/C pressure sensor.
PCM -- Engine Data 3 w/L47 (V8)-- A/C Relay Command: The scan tool displays ON or OFF. ON is displayed when the PCM
has energized the A/C clutch relay.
PCM -- Engine Output Controls w/L47 (V8)-- A/C Relay: The scan tool displays ON or OFF. OFF is displayed when an open
or short is detected in the A/C CLU relay ground circuit.