Scan Tool Output Control | Additional Menu Selection(s) | Description |
---|---|---|
A/C Orifice Relay | -- | The scan tool displays Commanded State: Off or On. This function allows you to command the A/C orifice solenoid to its maximum (On) or minimum (Off) diameters. |
Automatic/Manual HVAC Options | Set Options | The scan tool displays: Automatic HVAC w/ Dual Zone and Automatic HVAC w/o Dual Zone. This section allows you to change the control panel type in the IPM. |
Scan Tool Output Control | Additional Menu Selection(s) | Description |
---|---|---|
Afterblow | Set Options | Allows the blower motor to run after the ignition is turned OFF. |
Air Inlet Door Position | HVAC Motors | The scan tool displays Outside or Recirc selections. The selection drives the actuator to its min or max stops. |
Blower Motor | Miscellaneous | The scan tool displays Commanded State: None, Off or On. This function allows you to command the blower motor to its maximum (100%) or minimum (0%) speeds. |
Display(s) Test | Miscellaneous | The scan tool displays None, Off or On. This function commands the IP radio and HVAC control module to turn ON or OFF all lighted segments. |
Htr./Def./A/C Door Position | HVAC Motors | The scan tool displays Defrost or A/C selections. The selection drives the actuator to its min or max stops. |
Instant OAT Update | Miscellaneous | The scan tool displays Commanded State: None or On. Updates the IPM outside air temperature input to the current raw value. |
IPM Recalibration | Miscellaneous | Recalibrates the IPM |
Left Temp. Door Position | HVAC Motors | The scan tool displays Hot or Cold selections. The selection drives the actuator to its min or max stops. |
Recalibrate all Motors | Miscellaneous | The scan tool displays Commanded State: None or On. This function commands the actuators to drive to the stops fully opened and fully closed and relearn these endpoints. |
ReLearn Control Panel Type | Miscellaneous | The scan tool displays Commanded State: None or On. This function has the IPM relearn a new heater and A/C control. |
Right Temp. Door Position | HVAC Motors | The scan tool displays Hot or Cold selections. The selection drives the actuator to its min or max stops. |
Temperature Offset | Set Options | Allows for variation between driver set temperature and target, or desired, system discharge temperature. |
Scan Tool Output Control | Additional Menu Selection(s) | Description |
---|---|---|
A/C Relay | Engine Output Controls | The scan tool displays ON or OFF selections. This command allows you to turn the A/C relay ON or OFF. |