GM Service Manual Online
For 1990-2009 cars only

Removal Procedure


    Object Number: 182625  Size: SH
  1. Remove the instrument panel (I/P) cluster trim plate screws.
  2. Remove the steering column filler panel. Refer to Steering Column Opening Filler Replacement .
  3. Pull the I/P cluster trim plate rearward to disengage the retainers.
  4. Disconnect the electrical connector from the trip odometer and reset switch.
  5. Release the retainers on the trip odometer and reset switch by using a small flat-bladed tool.
  6. Remove the trip odometer and reset switch from the instrument panel cluster trim plate.

Installation Procedure


    Object Number: 182625  Size: SH
  1. Align the trip odometer and reset switch to the I/P cluster trim plate.
  2. Install the trip odometer and reset switch. Press into place until fully seated.
  3. Connect the electrical connector to the trip odometer and reset switch.
  4. Press the I/P cluster trim plate to the I/P to engage the retainers.
  5. Install the steering column filler panel. Refer to Steering Column Opening Filler Replacement .
  6. Notice: Refer to Fastener Notice in the Preface section.

  7. Install the I/P cluster trim plate screws.
  8. Tighten
    Tighten the screws to 2 N·m (18 lb in)