Step | Action | Value(s) | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|---|
1 | Did you perform the Instrument Cluster Diagnostic System Check? | -- | Go to Step 2 | |||||||
2 |
Is the voltage within the specified value? | 5 V | Go to Step 3 | Go to Step 4 | ||||||
3 | Measure the voltage from the boost/MAP sensor connector terminal C to terminal A. Is the voltage within the specified value? | 5 V | Go to Step 7 | Go to Step 8 | ||||||
4 | Inspect CKT 705 (GRY) for an open or a short to ground. Is the wiring OK? | -- | Go to Step 6 | Go to Step 7 | ||||||
5 | Repair the open on CKT 705 (GRY). Is the repair complete? | -- | -- | |||||||
6 |
Are the terminals OK? | -- | Go to Step 14 | Go to Step 15 | ||||||
7 | Connect a fused jumper from boost/MAP sensor connector terminal C to terminal B. Does the boost gauge meet specified value? | +10 | Go to Step 10 | Go to Step 11 | ||||||
8 | Inspect CKT 251 (BLK/WHT) wiring for an open. Is the wiring OK? | -- | Go to Step 16 | Go to Step 9 | ||||||
9 | Repair the open in CKT 251 (BLK/WHT). Is the repair complete? | -- | -- | |||||||
10 | Inspect the boost/MAP sensor connector for proper terminal contact. Is the terminal contact OK? | -- | Go to Step 12 | Go to Step 15 | ||||||
11 | Inspect CKT 891 (BLK) for an open or short to ground. Is the wiring OK? | -- | Go to Step 13 | Go to Step 17 | ||||||
12 | Replace the boost/MAP sensor. Is the repair complete? | -- | -- | |||||||
13 | Repair the open in CKT 891 (BLK). Is the repair complete? | -- | -- | |||||||
14 | Replace the instrument cluster (IPC).
Is the repair complete? | -- | -- | |||||||
15 | Repair the poor terminal contact. Is the repair complete? | -- | -- | |||||||
16 | Inspect connector C101 for proper terminal contact at terminal A1. Is the connector terminal contact OK? | -- | Go to Step 15 | |||||||
17 |
Are the terminal contacts OK? | -- | Go to Step 14 | Go to Step 15 |