Step | Action | Value(s) | Yes | No | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Did you perform the Instrument Cluster System Check? | -- | Go to Step 2 | |||||||||||||||||||
2 |
Does the measured voltage equal the specified value? | 10-15 V | Go to Step 4 | Go to Step 3 | ||||||||||||||||||
3 | Inspect CKT 439 (PNK) for an open. Is the wiring OK? | -- | Go to Step 17 | |||||||||||||||||||
4 |
Does the measured voltage equal the specified value? | 10-15 V | Go to Step 6 | Go to Step 5 | ||||||||||||||||||
5 | Inspect CKT 439 (PNK) for an open. Is the wiring OK? | -- | Go to Step 17 | |||||||||||||||||||
6 |
Does the measured voltage equal the specified value? | 10-15 V | Go to Step 8 | Go to Step 7 | ||||||||||||||||||
7 | Inspect CKT 451 (BLK/WHT) for an open. Is the wiring OK? | -- | Go to Step 18 | |||||||||||||||||||
8 | Measure voltage from the instrument cluster connector C2 terminal A10 to connector C1 terminal A14. Does the measured voltage equal the specified value? | 10-15 V | Go to Step 10 | Go to Step 9 | ||||||||||||||||||
9 | Inspect CKT 1250 (BLK) for an open. Is the wiring OK? | -- | Go to Step 20 | Go to Step 19 | ||||||||||||||||||
10 | Measure voltage from the instrument cluster connector C1 terminal A1 to ground. Does the measured voltage equal the specified value? | 10-15 V | Go to Step 12 | Go to Step 11 | ||||||||||||||||||
11 | Inspect CKT 40 (ORN) for an open. Is the wiring OK? | -- | Go to Step 20 | Go to Step 22 | ||||||||||||||||||
12 | Measure voltage from the instrument cluster connector C1 terminal B1 to ground. Does the measured voltage equal the specified value? | 10-15 V | Go to Step 14 | Go to Step 13 | ||||||||||||||||||
13 | Inspect CKT 40 (ORN) for an open between splice S214 and the instrument cluster. Is the wiring OK? | -- | Go to Step 22 | |||||||||||||||||||
14 |
Does the measured voltage equal the specified value? | 10-15 V | Go to Step 16 | Go to Step 15 | ||||||||||||||||||
15 | Inspect CKT 32 (YEL) for an open. Is the wiring OK? | -- | Go to Step 20 | Go to Step 23 | ||||||||||||||||||
16 |
Are all of the connector terminal contacts OK? | -- | Go to Step 25 | Go to Step 24 | ||||||||||||||||||
17 | Repair the open in CKT 439 (PNK). Did you complete the repair? | -- | -- | |||||||||||||||||||
18 | Repair the open in CKT 451(BLK/WHT). Did you complete the repair? | -- | -- | |||||||||||||||||||
19 | Repair the open in CKT 1250 (BLK). Did you complete the repair? | -- | -- | |||||||||||||||||||
20 | Inspect connector C200 for proper terminal contact at terminal F12. Is the terminal contact OK? | -- | -- | |||||||||||||||||||
21 | Repair the poor terminal contact. Did you complete the repair? | -- | -- | |||||||||||||||||||
22 | Repair the open in CKT 40 (ORN). Did you complete the repair? | -- | -- | |||||||||||||||||||
23 | Repair the open in CKT 32 (YEL). Did you complete the repair? | -- | -- | |||||||||||||||||||
24 | Repair the poor terminal contact. Did you complete the repair? | -- | -- | |||||||||||||||||||
25 | Replace the instrument cluster. Did you complete the repair? | -- | -- |
Step | Action | Value(s) | Yes | No | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Did you perform the Instrument Cluster System Check? | -- | Go to Step 2 | |||||||||||
2 |
Does the measured voltage equal the specified value? | 10-15 V | Go to Step 4 | Go to Step 3 | ||||||||||
3 | Inspect CKT 439 (PNK) for an open. Is the wiring OK? | -- | Go to Step 11 | |||||||||||
4 | Measure the voltage from the instrument cluster connector terminal B9 to ground (w/UB3) or terminal B5 (w/U23) to ground. Does the measured voltage equal the specified value? | 10-15 V | Go to Step 6 | Go to Step 5 | ||||||||||
5 | Inspect CKT 439 (PNK) for an open between splice S299 and the instrument cluster. Is the wiring OK? | -- | Go to Step 13 | |||||||||||
6 | Measure the voltage from the instrument cluster connector terminal B3 to ground. Does the measured voltage equal the specified value? | 10-15 V | Go to Step 8 | Go to Step 7 | ||||||||||
7 | Inspect CKT 439 (PNK) for an open. Is the wiring OK? | -- | Go to Step 13 | |||||||||||
8 | Measure the voltage from the instrument cluster connector terminal B1 to terminal B6 and terminal B7. Does the measured voltage equal the specified value in both cases? | 10-15 V | Go to Step 10 | Go to Step 9 | ||||||||||
9 | Inspect CKT 451 for an open. Is the wiring OK? | -- | Go to Step 14 | |||||||||||
10 | Inspect the instrument cluster connector for proper terminal contact at the following terminals:
Are the connectors OK? | -- | Go to Step 12 | Go to Step 15 | ||||||||||
11 | Repair the open in CKT 439 (PNK). Did you complete the repair? | -- | -- | |||||||||||
12 | Replace the instrument. Did you complete the repair? | -- | -- | |||||||||||
13 | Repair the open to CKT 439 (PNK). Did you complete the repair? | -- | -- | |||||||||||
14 | Repair the open to CKT 451 (BLK/WHT). Did you complete the repair? | -- | -- | |||||||||||
15 | Repair the poor terminal contact. Did you complete the repair? | -- | -- |
Step | Action | Value(s) | Yes | No | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Did you perform the Instrument Cluster System Check? | -- | Go to Step 2 | |||||||||||
2 |
Does the measured voltage equal the specified value? | 10-15 V | Go to Step 3 | Go to Step 13 | ||||||||||
3 | Measure the voltage from the instrument cluster connector terminal B2 to terminal B3. Does the measured voltage equal the specified value? | 10-15 V | Go to Step 7 | Go to Step 4 | ||||||||||
4 | Inspect CKT 1250 (BLK) for an open. Is the wiring OK? | -- | Go to Step 6 | Go to Step 5 | ||||||||||
5 | Repair the open to CKT 1250 (BLK). Did you complete the repair? | -- | -- | |||||||||||
6 | Inspect the in-line connector C200 terminal F12 for proper terminal contact. Is the contact OK? | -- | Go to Step 21 | |||||||||||
7 | Measure the voltage from the instrument cluster connector terminal B2 to terminal A8 and terminal A17. Does the measured voltage equal the specified value? | 10-15 V | Go to Step 11 | Go to Step 8 | ||||||||||
8 | Inspect CKT 451 (BLK/WHT) for an open. Is the wiring OK? | -- | Go to Step 10 | Go to Step 9 | ||||||||||
9 | Repair the open to CKT 451 (BLK/WHT) for an open. Did you complete the repair? | -- | -- | |||||||||||
10 | Inspect the in-line connector C200 terminal H11 for proper terminal contact. Is the contact OK? | -- | Go to Step 21 | |||||||||||
11 | Measure the voltage from the instrument cluster connector terminal B4 to ground. Does the measured voltage equal the specified value? | 10-15 V | Go to Step 12 | Go to Step 13 | ||||||||||
12 | Measure the voltage from the instrument cluster connector terminal A15 to ground. Does the measured voltage equal the specified value? | 10-15 V | Go to Step 14 | Go to Step 13 | ||||||||||
13 | Inspect CKT 439 (PNK) for an open. Is the wiring OK? | -- | Go to Step 19 | |||||||||||
14 |
Does the measured voltage equal the specified value? | 10-15 V | Go to Step 18 | Go to Step 15 | ||||||||||
15 | Inspect CKT 40 (ORN) for an open. Is the wiring OK? | -- | Go to Step 17 | Go to Step 16 | ||||||||||
16 | Repair the open to CKT 40 (ORN). Did you complete the repair? | -- | -- | |||||||||||
17 | Inspect connector C200 terminal D4 for proper terminal contact. Is the contact OK? | -- | Go to Step 21 | |||||||||||
18 | Inspect the instrument cluster connector for proper terminal contact at the following terminals:
Are the connectors OK? | -- | Go to Step 20 | Go to Step 21 | ||||||||||
19 | Repair the open on CKT 349 (PNK). Did you complete the repair? | -- | -- | |||||||||||
20 | Replace the instrument. Did you complete the repair? | -- | -- | |||||||||||
21 | Repair the poor terminal contact. Did you complete the repair? | -- | -- |
Step | Action | Value(s) | Yes | No | ||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Did you perform the Instrument Cluster Diagnostic System Check? | -- | Go to Step 2 | |||||||||||||||||||||||||
2 |
Does the measured voltage equal the specified value? | 10-15 V | Go to Step 4 | Go to Step 3 | ||||||||||||||||||||||||
3 | Inspect CKT 439 (PNK) for an open. Is the wiring OK? | -- | Go to Step 17 | |||||||||||||||||||||||||
4 |
Does the measured voltage equal the specified value? | 10-15 V | Go to Step 6 | Go to Step 5 | ||||||||||||||||||||||||
5 | Inspect CKT 439 (PNK) for an open between splice S299 and the instrument cluster. Is the wiring OK? | -- | Go to Step 19 | |||||||||||||||||||||||||
6 | Measure the voltage from the instrument cluster connector C2 terminal F16 to terminal F7 and terminal F8. Does the measured voltage equal the specified value? | 10-15 V | Go to Step 8 | Go to Step 7 | ||||||||||||||||||||||||
7 | Inspect CKT 451 for an open. Is the wiring OK? | -- | Go to Step 20 | |||||||||||||||||||||||||
8 | Measure the voltage from the instrument cluster connector C2 terminal F16 to terminal E11 and terminal E12. Does the measured voltage equal the specified value in both cases? | 10-15 V | Go to Step 10 | Go to Step 9 | ||||||||||||||||||||||||
9 | Inspect CKT 1250 (BLK) for an open. Is the wiring OK? | -- | Go to Step 21 | |||||||||||||||||||||||||
10 | Measure the voltage from the instrument cluster connector C2 terminal F5 to ground. Does the measured voltage equal the specified value? | 10-15 V | Go to Step 12 | Go to Step 11 | ||||||||||||||||||||||||
11 | Inspect CKT 439 (PNK) for an open. Is the wiring OK? | -- | Go to Step 19 | |||||||||||||||||||||||||
12 | Measure the voltage from the instrument cluster connector C2 terminal F4 to ground. Does the measured voltage equal the specified value? | 10-15 V | Go to Step 14 | Go to Step 13 | ||||||||||||||||||||||||
13 | Inspect CKT 147 (LT GRN) for an open. Is the wiring OK? | -- | Go to Step 22 | |||||||||||||||||||||||||
14 |
Does the measured voltage equal the specified value? | 10-15 V | Go to Step 16 | Go to Step 15 | ||||||||||||||||||||||||
15 | Inspect CKT 40 (ORN) for an open. Is the wiring OK? | -- | Go to Step 23 | |||||||||||||||||||||||||
16 |
Are the connectors OK? | -- | Go to Step 18 | Go to Step 24 | ||||||||||||||||||||||||
17 | Repair the open in CKT 439 (PNK). Did you complete the repair? | -- | -- | |||||||||||||||||||||||||
18 | Replace the instrument. Did you complete the repair? | -- | -- | |||||||||||||||||||||||||
19 | Repair the open in CKT 439 (PNK). Did you complete the repair? | -- | -- | |||||||||||||||||||||||||
20 | Repair the open in CKT 451 (BLK/WHT). Did you complete the repair? | -- | -- | |||||||||||||||||||||||||
21 | Repair the open in CKT 1250 (BLK). Did you complete the repair? | -- | -- | |||||||||||||||||||||||||
22 | Repair the open in CKT 147 (LT GRN). Did you complete the repair? | -- | -- | |||||||||||||||||||||||||
23 | Repair the open in CKT 40 (ORN). Did you complete the repair? | -- | -- | |||||||||||||||||||||||||
24 | Repair the poor terminal contact. Did you complete the repair? | -- | -- |