Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Horns System Check? | -- | Go to Step 2 | Go to Horns System Check |
2 | Disconnect the horn relay. Are the horns on? | -- | Go to Step 4 | Go to Step 3 |
3 | Connect a test lamp between relay terminal 86 and terminal 85. Does the test lamp light? | -- | Go to Step 6 | Go to Step 5 |
4 | Repair CKT 29 (DK GRN) for a short to B+. Is the repair complete? | -- | Go to Horns System Check | -- |
5 | Replace the horn relay. Is the repair complete? | -- | Go to Horns System Check | -- |
6 |
Are the horns on? | -- | Go to Step 7 | Go to Step 8 |
7 | Repair CKT 28 (BLK) for a short to ground. Is the repair complete? | -- | Go to Horns System Check | -- |
8 | Replace the horn switch. Is the repair complete? | -- | Go to Horns System Check | -- |